Possible complications include, but are not limited to, the following: Two passes of CAT RX with the Penumbra ENGINE resulted in TIMI 3 flow restoration and retrieval of the distal emboli from the PDA (Figure 3). Reuse may result in canister cracking or vacuum filter blockages, which may result in the inability to aspirate. Figure 3. As part of the Indigo Aspiration System, the Indigo CAT RX Aspiration Catheters and Indigo Separator 4 are indicated for the removal of fresh, soft emboli and thrombi from vessels in the coronary and peripheral vasculature. Hemoglobin and hematocrit levels should be monitored in patients with >700 mL blood loss from the clot aspiration procedure. Do not use automated high-pressure contrast injection equipment with the INDIGO CAT RX Aspiration Catheter because it may damage the device. Do not use the INDIGO Aspiration System with a pump other than the Penumbra Aspiration Pump. $450.00) Model #: CAT8TORQ85 OEM: Penumbra System Expiration Date: 2022 Size: 8Fr x 85cm . This content is not intended to offer professional medical advice. Learn more about Lightning. Next Article Learn more about Lightning. The Indigo System CAT3, CAT5, CAT6, CAT8 and CATD ?are engineered to be robust, durable, and trackable for use in the peripheral anatomy. The patient was brought to the catheterization laboratory for angiography that showed stagnant flow through the saphenous vein graft (SVG; Figure 1). QUICK VIEW. (CAT3, CAT RX, CAT5, CAT6, CAT8, and CATD) and patented Separator technology, which maintains continuous aspiration and helps limit clogging of the catheters tip during the procedure. Aspiration Tubing Intended Use The procedure time was short (median of 37 minutes)the shortest demonstrated so far in an investigational device exemption (IDE) trial on patients with pulmonary embolism. She had a recent embolic cerebrovascular accident (CVA) with a hemorrhagic conversion and right-sided hemiparesis but was otherwise known to be very functional. In our practice, we have been able to more accurately define percutaneous transluminal coronary angioplasty and stent length as a result of this increased visualization. The INDIGO SEPARATOR is not intended for use as a guidewire. Do not resterilize or reuse. INDIGO Aspiration Catheters and Separators: As part of the INDIGO Aspiration System, the INDIGO Aspiration Catheters and Separators are indicated for the removal of fresh, soft emboli and thrombi from vessels of the peripheral arterial and venous systems, and for the treatment of pulmonary embolism. Potential Adverse Events Possible complications include, but are not limited to, the following: allergic reaction and anaphylaxis from contrast media; acute occlusion; air embolism; arteriovenous fistula; death; device malfunction; distal embolization; emboli; false aneurysm formation; hematoma or hemorrhage at access site; inability to completely remove thrombus; infection; hemorrhage; ischemia; kidney damage from contrast media; neurological deficits including stroke; vessel spasm, thrombosis, dissection, or perforation; intimal disruption; myocardial infarction; emergent surgery; fibrillation; hypotension; respiratory failure; peripheral thromboembolic events. Indigo Disposable Separator 8, 150 cm Length, 0.072 in. Chris Metzger, MD
If such use is necessary, this equipment and the other equipment should be observed to verify that they are operating normally. Precautions The safety and effectiveness of this device for use in the treatment of ST-Elevation Myocardial Infarction (STEMI) has not been established. . The treatment of arterial and venous thrombus is challenging. Indigo Aspiration Catheters (CAT) are the foundation of Penumbra's Indigo System.The Indigo System CAT3, CAT5, CAT6, CAT8 and CATD are engineered to be robust, durable, and trackable for use in the peripheral anatomy. To avoid risk of electrical shock, this equipment must only be connected to a supply mains with protective earth. 2017;377:2240-2252. Disclosures: Consultant to Penumbra, Inc. An 83-year-old woman transferred from an outside hospital presented with acute shortness of breath, was hypotensive, and was intubated. Prior to use, please refer to the Instructions for Use for complete product indications, contraindications, warnings, precautions, potential adverse events, and detailed instructions for use. With a maximised inner diameter of 0.08 (2.1 mm) and a 7 French (2.3 mm) outer diameter, CAT7 is 93% the size of CAT8, now with a lower profile. The complaint has been evaluated. excellent trackability, and similar power to the CAT8 Penumbra catheter that was previously used for this . The INDIGO Aspiration Tubing: Use of LIGHTNING Aspiration Tubing adjacent to other equipment should be avoided because it could result in improper operation. sjaymathewsmd@gmail.com
Indigo System CAT RX has been designed to address the limitations of traditional treatment options with manual aspiration. Potential Adverse Events The product-specific content of this website is intended for use by healthcare professionals only. Ruby Coil, POD, and Packing Coil are large-volume coils designed for embolization of the peripheral arterial and venous systems. At our institutions, we are using CAT RX for patients who present with fresh soft thrombi or emboli. CAT8XTORQ115KIT-NS. The Indigo SystemCAT3, CAT5, CAT6, CAT8 and CATD are engineered to be robust, durable, and trackable for use in the peripheral anatomy. Pharmacomechanical catheter-directed thrombolysis for deep-vein thrombosis. This allowed prompt treatment of patients with minimal intensive care unit days and early discharge from the hospital. Possible complications include, but are not limited to, the following: acute vessel occlusion; air embolism; allergic reaction and anaphylaxis from contrast media or device material; anemia; arrhythmia; arteriovenous fistula; cardiac injury, cardiac perforation, cardiac tamponade; cardio-respiratory arrest; compartment syndrome; death; emboli; emergent surgery; foreign body embolization; hematoma or hemorrhage at access site; hemoptysis; hemorrhage; hypotension/hypertension; infarction leading to organ damage; infection; ischemia; myocardial infarction; neurological deficits including stroke; pneumothorax; pseudoaneurysm; renal impairment or acute renal failure from contrast media; residual thrombus due to inability to completely remove thrombus or control blood flow; respiratory failure; valvular damage; vessel spasm, thrombosis, dissection (intimal disruption), or perforation. The Indigo System aspiration catheters are available in a range of lengths and diameters that, when connected to the Penumbra ENGINE pump, can atraumatically remove the thrombus present in various peripheral vascular beds. It is intended for use in the revascularization of patients with acute ischemic stroke secondary to intracranial large vessel occlusions. Copyright 2022 Penumbra, Inc. All rights reserved. The patient had reported intermittent chest discomfort for 3 days, with some improvement with his daily medications. If the device is forcefully retracted at extreme angles during removal from the packaging, damage such as this may occur. Do not re-infuse blood or fluid from the canister back into the patient. In some cases, we have also seen a reduction in glycoprotein IIb/IIIa inhibitor usage (which may be associated with higher rates of bleeding). Throughout each case, Lightning provides procedural feedback via audiovisual cues. Indigo Aspiration System (CAT RX and Separator 4)- Penumbra Engine Pump and Canister. Do not use in an oxygen rich environment. Return all damaged devices and packaging to the manufacturer/distributor. 2018;72:1589-1596. chronic clot, atherosclerotic plaque) The cerebral vasculature Warnings The INDIGO Aspiration System should only be used by physicians who have received appropriate training in interventional techniques. Available in a selection of sizes, the CAT family can provide access to distal peripheral vessels of the upper and lower extremities, including below the knee. This content is not intended to offer professional medical advice. Related Items. The initial angiogram confirmed an occlusion with extensive thrombus burden of a dominant left circumflex artery and TIMI 0 flow (Figure 1). Do not use in oxygen rich environment. The Penumbra ENGINE addresses the limitations of traditional treatment options by providing sustained mechanical power aspiration for the duration of the procedure to help maximize efficiency of thrombus removal. Using the usual telescoping technique of the sheath, the CAT8 and SEP8 were used in tandem to aspirate the thrombus using sustained aspiration with Penumbra ENGINE. Catheters; CAT8 KIT Indigo System Aspiration Catheter 8 and Aspiration Tubing - XTORQ - 8Fr x 115cm . Excessive aspiration or failure to close the INDIGO Aspiration Tubing when aspiration is complete is not recommended. Enter your email address and we will contact you. Bradenton Cardiology Center/Manatee Memorial Hospital
Director of Cardiac Catheterization Lab, PERT & Structural Heart
Saxon RR, Benenati JF, Teigen C, et al. Penumbra introduced the Ruby Coil in 2013, followed by the launch of PODin 2014 and Packing Coil in 2015. A 65-cm 8-F Destination sheath (Terumo Interventional Systems) was advanced into the right pulmonary artery, first over a telescoping balloon tip catheter and stiff angle Glidewire (Terumo Interventional Systems). These benefits may suggest a reduction to cost of care, improved patient outcomes, and changes to the procedural algorithm. The system uses Penumbra's RED reperfusion catheters. Ruby Coil, POD, and Packing Coil work in conjunction to help facilitate simplified and efficient embolization procedures. Penumbra Aspiration Pump: The Penumbra Aspiration Pump is indicated as a vacuum source for Penumbra Aspiration Systems. Do not use INDIGO SEPARATOR 4 to macerate or retrieve thrombus distal to the catheter tip. Because the patient was not a candidate for thrombolysis, the decision was made to intervene with the Indigo System CAT8XTORQ115 and SEP 8, which were advanced sequentially into the right then left pulmonary artery. As part of the Indigo Aspiration System, the Indigo CAT RX Aspiration Catheters and Indigo Separator 4 are indicated for the removal of fresh, soft emboli and thrombi from vessels in the coronary and peripheral vasculature. The Penumbra Aspiration Pump is indicated as a vacuum source for Penumbra Aspiration Systems. Do not reuse. Penumbra CAT8TORQ85 CAT8 Indigo Aspiration Catheter 8, TORQ tip, 85cm , 8Fr., Peripheral Thrombectomy Mechanical one each . INDIGO Aspiration System Intended Use o The Penumbra Indigo System Separator is intended for use with our Indigo System's family of catheters to enable the removal of a wide range of thrombus. The Penumbra ENGINE is intended as a vacuum source for Penumbra Aspiration Systems. Sista A. Indigo aspiration system for acute pulmonary embolism. Contraindications allergic reaction and anaphylaxis from contrast media; acute occlusion; air embolism; arteriovenous fistula; death; device malfunction; distal embolization; emboli; false aneurysm formation; hematoma or hemorrhage at access site; inability to completely remove thrombus; infection; hemorrhage; ischemia; kidney damage from contrast media; neurological deficits including stroke; vessel spasm, thrombosis, dissection, or perforation; intimal disruption; myocardial infarction; emergent surgery; fibrillation; hypotension; respiratory failure; peripheral thromboembolic events. Mathews SJ, Brown C, Kolski B, et al. Use of this equipment adjacent to or stacked with other equipment should be avoided because it could result in improper operation. BJC Cardiology
A minimally-invasive device, Indigo enables the restoration of blood flow in such cases as acute limb ischemia and venous thrombus. The INDIGO Aspiration Tubing is intended to connect the INDIGO Aspiration Catheters to the Penumbra Aspiration Pump. If the cause cannot be determined, withdraw the device or system as a unit. CAT RX mechanical aspiration system powered by Penumbra ENGINE in comparison to manual syringe-based aspiration. Common emitters (such as RFID emitters, security systems, diathermy equipment, and portable transmitters) should not be used in close proximity to the Penumbra ENGINE as they can interfere with and result in degradation of the performance of the equipment. Do not use in the presence of a flammable anesthetic mixture with air or nitrous oxide. Ballad CVA Heart & Vascular Institute
Figure 2. After one pass with mechanical thrombectomy using CAT RX, the thrombus was removed and flow was restored to the pedal arch via the plantar posterior tibial artery (Figure 2 and Figure 3). The Indigo System with Lightning Aspiration Tubing is an intelligent aspiration system powered by Penumbra ENGINE. When performing aspiration, ensure that the INDIGO Aspiration Tubing is open for only the minimum time needed to remove thrombus. Potential Adverse Events Possible complications include, but are not limited to, the following: allergic reaction and anaphylaxis from contrast media; acute occlusion; air embolism; arrhythmia/fibrillation; arteriovenous fistula; death; device malfunction; distal embolization; emergent surgery; false aneurysm formation; hematoma, hemorrhage, or blood loss at access site; hematoma, hemorrhage, or blood loss; hypotension; inability to completely remove thrombus or control blood flow; infection; ischemia; kidney damage from contrast media; myocardial infarction; neurological deficits including stroke; respiratory failure; thromboembolic events; vascular complications (including vessel spasm, thrombosis, intimal disruption, dissection, or perforation). The Indigo System can provide immediate mechanical relief by extracting clot while decreasing pressures using sustained power aspiration without the need for thrombolytics. Within 72 hours, repeat echocardiography showed RV/LV ratio improvement from 1.43 to 0.98. With automatic valve control, Lightning can help the physician focus on optimising thrombus removal procedures. The four cathetersCAT3, 5, 6, & 8are robust, durable, trackable, and suited for the peripheral anatomy. Penumbra System CAT8 INDIGO System Aspiration Catheter 8 - XTORQ - 8Fr x 115cm - Non-Expired: 8Fr x 115cm 0: Contact Us: RBY2C0305 gus.theodos@bjc.org; @gtheodosmd
Cook Medical) with the Indigo System (Penumbra, Inc.) using a CAT8 catheter and SEP8 separator to maximise the debris removal. CAT8 Indigo System Aspiration Catheter - TORQ - 8Fr x 85cm Penumbra System. Tip directionality for circumferential aspiration, Live feedback during procedure with integrated clot catcher, Penumbra ENGINE is capable of delivering and maintaining nearly pure vacuum (-29 inHg or 98.2 kPa) with the disposablePenumbra ENGINE Canister. Use the INDIGO Aspiration System in conjunction with fluoroscopic visualization. The Indigo Separator is advanced and retracted through the corresponding size Indigo catheter at the proximal margin of the primary occlusion to facilitate clearing of the thrombus from the catheter tip. We presented our initial experience at the American College of Cardiologys (ACC) 68th Annual Scientific Session, which showed promising results for mechanical power aspiration for thrombus removal during percutaneous intervention using CAT RX.3 This retrospective case series included 59 patients from four institutions around the United States. The Indigo Aspiration System is contraindicated in: The combination of computer- aided aspiration and large-lumen catheter engineering form Lightning 7 and Lightning 12: the latest generation in clot removal technology. The CAT8 is indicated for removal of emboli and thrombi from the peripheral . Unit may overheat and shut off or fail to restart if run for extended periods of time without airflow. Do not use kinked or damaged devices. Unrestrained torquing or forced insertion of the catheter or SEPARATOR against resistance may result in damage to the device or vessel. Potential Adverse Events Possible complications include, but are not limited to, the following: allergic reaction and anaphylaxis from contrast media; acute occlusion; air embolism; arrhythmia/fibrillation; arteriovenous fistula; death; device malfunction; distal embolization; emergent surgery; false aneurysm formation; hematoma, hemorrhage, or blood loss at access site; hematoma, hemorrhage, or blood loss; hypotension; inability to completely remove thrombus or control blood flow; infection; ischemia; kidney damage from contrast media; myocardial infarction; neurological deficits including stroke; respiratory failure; thromboembolic events; vascular complications (including vessel spasm, thrombosis, intimal disruption, dissection, or perforation). Penumbra's CAT family of catheters is engineered to be robust, trackable, atraumatic, and well suited to the peripheral anatomy where clots can form in long segments. Do not advance, retract or use any component of the INDIGO System against resistance without careful assessment of the cause using fluoroscopy. window.dataLayer = window.dataLayer || []; Penumbra CAT8XTORQ115 CAT8 Indigo System Aspiration Catheter 8F Item Past Expiration +1(833)330-3033. Further evaluation of the returned device revealed kinks in the catheter shaft. The atraumatic tip and small catheter French size of the CAT8 device allows for easy tracking and maneuvering through the vasculature and selective debulking of thrombus from lobar branches of the pulmonary arterial tree. 8: Add BMK6F95M-NE . Indication For Use This case illustrates the vast improvement in aspiration technology with an easy-to-deliver, trackable catheter that maintains sustained aspiration for the duration of the procedure. Possible complications include, but are not limited to, the following: Distal emboli causing PDA occlusion after manual aspiration. Final angiographic result of SVG. K180412. The device is intended for single use only. Contraindications The large aspiration lumen and highly trackable, low-profile design coupled with the power of the Penumbra ENGINE resulted in the successful removal of the emboli in one pass. Penumbra, a US-based provider of advanced therapies, has enrolled the first patient into the CHEETAH clinical study, designed to evaluate the safety and performance of the Indigo System with CAT RX Aspiration Catheter in the coronary vessels. The device is intended for single use only. To avoid the risk of electrical shock, this equipment must only be connected to a supply mains with protective earth. PENUMBRA, INC. INDIGO SYSTEM ASPIRATION CATHETER 8 DXE: Back to Search Results: Model Number CAT8XTORQ115KIT-S: Device Problems Break (1069); Physical Resistance/Sticking (4012) Patient Problem No Clinical Signs, Symptoms or Conditions (4582) Event Date 05/19/2021: Available in a selection of sizes, the CAT family can provide access to distal peripheral vessels of the upper and lower . Do not use automated high-pressure contrast injection equipment with the INDIGO Aspiration Catheter because it may damage the device. 2018;29:92-100. This ability of lobar thrombectomy likely allowed EXTRACT-PE to be the first endovascular IDE, pulmonary embolism trial that has reported statistically significant reduction in on-table systolic pulmonary artery pressures. 1. The patients symptoms normalized, the electrocardiogram stabilized, and the acute MI was immediately resolved. INDIGO Aspiration System with LIGHTNING Aspiration Tubing Indication for Use Figure 2. The INDIGO SEPARATOR is not intended for use as a guidewire. Final angiography was performed, showing complete resolution of the underlying lesion (Figure 2). function gtag(){dataLayer.push(arguments);} If repositioning of the INDIGO CAT RX Aspiration Catheter is necessary during the revascularization procedure, such repositioning should be performed over an appropriate guidewire using standard guidewire techniques. The procedure was completed with the same catheter. Available in a selection of sizes, the CAT family can provide access to distal peripheral vessels of the upper and lower . Maintain a constant infusion of appropriate flush solution. N Engl J Med. If repositioning of the Indigo CAT RX Aspiration Catheter is necessary during the revascularization procedure, such repositioning should be performed over an appropriate guidewire using standard guidewire techniques. Use of LIGHTNING Aspiration Tubing adjacent to other equipment should be avoided because it could result in improper operation. Caution: Prior to use, please refer to the Instructions for Use for complete product indications, contraindications, warnings, precautions, potential adverse events, and detailed instructions for use. right-arrow Continuous Aspiration Mechanical Thrombectomy Catheters (CAT) are the foundation of Penumbra's Indigo System. As part of the Indigo Aspiration System, the Indigo CAT RX Aspiration Catheters and Indigo Separator 4 are indicated for the removal of fresh, soft emboli and thrombi from vessels in the coronary and peripheral vasculature. Penumbra CAT8XTORQ115 CAT8 Indigo System Aspiration Catheter 8F Item Past Expiration. Use the INDIGO Aspiration System in conjunction with fluoroscopic visualization. Presented at: American College of Cardiologys 68th Annual Scientific Session; March 1618, 2019; New Orleans, LA. Penumbra's Indigo Aspiration System, launched in 2014, is designed to remove clot from arteries and veins in the peripheral vasculature, and for treatment of pulmonary embolism. Penumbra System CAT8 KIT Indigo System Aspiration Catheter 8 and Aspiration Tubing - XTORQ - 8Fr x 115cm - Non-Expired: 8Fr x 115cm 0: Contact Us: . The Indigo Separator is advanced and retracted through the corresponding size Indigo catheter at the proximal margin of the primary occlusion to facilitate clearing of the thrombus from the catheter tip. Return all damaged devices and packaging to the manufacturer/distributor. We expect the results to further refine and improve our technique for mechanical aspiration and fine-tune the use of CAT RX for patients with high thrombus burden. Do not use in the presence of a flammable anesthetic mixture with air or nitrous oxide. Her heart rate was 110 beats per minute, elevated troponin levels at 4.5 ng/mL, and elevated brain natriuretic peptide at 1,164 pg/mL. Presented at: Vascular InterVentional Advances (VIVA); November 47, 2019; Las Vegas, Nevada. A Penumbra CAT8 catheter was placed into the right upper lobe, right middle lobe, and right lower lobe, and aspiration with a separator was performed.