1. If you are scanning the loggers then be sure to scan the bar code on the logger itself and not the one on the inverter's spec label, see examples of the logger bar codes below: If the connection is weak (1-2 bars) then it is recommended to install aWiFirange extender to boost the signal strength where the logger is going to be. Then click the Its flashing. Continue with Recommended Cookies, Home solis solis S3-WIFI WiFi Stick Datalogger Installation Guide, WiFi Stick Datalogger QuickInstallation ManualVersion: 3.1. Step 5: Scan the SN number of the datalogger or manually input it.Note: Scan the datalogger SN, NOT the inverter SN. This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. Standard Warranty Document : Solis An example of data being processed may be a unique identifier stored in a cookie. Internal DC Short: In the inverter head, or the wirebox? After you connect verify the WIFI stick sees the inverter. No, Modified on: Fri, Jun 10, 2022 at 11:55 AM. All is fine for about a week and then I noticed that the system would go offline a couple of times throughout the day (morning and night) with varying durations. Well also assume you agree to the way we use cookies and are ok with it as described in our Privacy policy, unless you choose to disable them altogether through your browser. on solis S3-WIFI WiFi Stick Datalogger Installation Guide, solis GPRS Stick Datalogger Instruction Manual. Establecer el estndar de red personalizado Definido por usuario, Valores de la configuracin USER DEF para red 240v y 480v, Procedimiento de actualizacin remota de firmware, Reduccin de la potencia de salida del inversor Solis monofsico, Instalacin de cable RS-485 con conector circular, Configuracin de la direccin en inversor trifsico, Restablecer WiFi-Stick a la configuracin de fbrica, Registro de usuario final al sistema de monitoreo. solis app gone off-line MATTYON Apr 14, 2022 hi all my Solis app has stopped giving info since about 1 am with message "Current plant offline, Please check network connection of plant device" i wont get to it until tonight has anyone seen this before is it just the wifi (or has the whole system gone down) and will re-booting the system put it right Victor is the author of this solution article. Connect to the inverter (to get power) 3. Reliability Safety Capacity WiFi Data Logger. Soli Wifi Datalogger Installation Instructions (For APP) Status indicator, easy to display working status, RESET button, one key to send data, convenient debugging, Number of connected inverters (Connect the inverters by RS485 cables. Some of our partners may process your data as a part of their legitimate business interest without asking for consent. I haven't been able to log onto it after many attempts. Thanks Peter. it has come back on line, so it is obviously a connection issue, Xi Jinping must have forgot to reboot the GFW this morning, Copyright 2000- 2023 Boards Software Limited, If you have a new account but are having problems posting or verifying your account, please email us on, Hello All, This is just a friendly reminder to read the Forum Charter where you wish to post before posting in it. Open the SolisCloud app on your phone. Solis Data Logger Server Information - firewall exceptions Step 6: Plant creation succeeds. Things (IOT). 2. Category: Monitoring and Communication Scan the bar code on the logger [note: a cellular logger is shown in the photo but it has the same scanning process as theWiFilogger], Tap "OK" in the top right corner once the logger serial number shows up. Establecer el estndar de red personalizado Definido por usuario, Valores de la configuracin USER DEF para red 240v y 480v, Procedimiento de actualizacin remota de firmware, Reduccin de la potencia de salida del inversor Solis monofsico, Instalacin de cable RS-485 con conector circular, Configuracin de la direccin en inversor trifsico, Restablecer WiFi-Stick a la configuracin de fbrica, Registro de usuario final al sistema de monitoreo. Open theSolisCloudapp on your phone. cordless phone, concrete wall, PV panel and metal wall, to ensure the communication quality. Hi Everyone, I got some help with the Ginlong Wifi and I have been able to set the system up and log onto the Ginlong monitoring websitebut the system says it is 'loading' but no data is shown on the site. Ginlong Solis is one of the world's recognised manufacturers of string solar inverters. Insert the datalogger to the inverter COM port. Copyright@2020 Ginlong Technologies All rights reserved, If the network is not appearing, press and hold the Reset button down for 10 seconds until both NET and COM lights start to flash simultaneously, This network must be 2.4GHz as 5GHz networks are not supported. SolisCloud App helps you manage PV plant: 1. PDF WiFi Instructions - Solis inverters are designed to last longer! Data Logging Stick: GPRS/WiFi. 125K Multi-Input Inverter: No Paralleled DC Strings Allowed! WiFi Instructions - Solis inverters are designed to last longer! Connect wifi to the Wi-Fi stick to the interface on the inverter 2. *, We appreciate your effort and will try to fix the article. Connect one end of an ethernet cable to LAN stickand other end directly to a computer. I'm having the same issue, just tried setting it up but says it's offline, light on the stick is red, anything I should be checking? This equipment should be installed and operated with a minimum distance of 20cm between the radiator & your body. Once you've connected to the "AP" network, return toSolisCloudand then look for the home network that you wish to connect the logger to. Solis Data Loggers : Solis Unscrew the protective cap over the green COM port on the bottom of the inverter's wire box. The delay in putting it in place was due to a bug/update issue. See if this helps you out https://www.youtube.com/watch?v=0F0aGeTOYw8. Connect to the datalogger - AP_XXXXXXXXXX, 3. It is highly recommended to first connect your phone to the home network that you wish to connect theWiFilogger to. Select Network, fill in the IP address assigned by the router/network administrator LAN Stick - DLS-L 1: Connect LAN stick to operational inverter to provide power to LAN stick. did it re-connect on its own or did it need a re-boot. signal at the inverter for there to be a stable connection. Yes my data logger also glows red as well, does appear to be a LED keepalive in the unit to show its still transmitting data to the mothership. S-Energy 320W modules, Terminal Torque Specs by Inverter Model Series, Advisory Bulletin July 2019 - New DC Switch Color of Red on Single Phase, Application Notes: Rapid Shutdown AC Wiring with Multiple Inverters, Rule 21 Phase 1 July 26th Changes 1P and 3P, Solis RSD Letter For Jurisdiction Acceptance, Spring Terminals Installation and Removal, RHI-1P(5-10)K-5G with BYD HV Commissioning Guide, Solis RHI-1P(5-10)K-HVES-5G Installation Guide, 5 of 20 - Installing the External Meter and CTs, 7 of 20 - Inverter Menu Overview and Selecting the Grid Standard, 8 of 20 - Installing & Commissioning the BYD B-Box HV Battery, 9 of 20 - Installing LG Chem RESU10H Battery (Mounting), 10 of 20 - Installing LG Chem - Wiring and Commissioning, 11 of 20 - Energy Storage Operating Modes - Self Use, 12 of 20 - Energy Storage Operating Modes - Feed-In-Priority, 13 of 20 - Installing the Solis Autotransformer, 14 of 20 - Installing the Backup Loads Subpanel and Selecting Critical BreakersLoad, 15 of 20 - Energy Storage Operating Modes - Backup and Off-Grid Modes, 17 of 20 - Module-Level Rapid Shutdown (MLRSD), 18 of 20 - SolisCloud Monitoring Platform, Installation Overview & Single-Line Diagrams, Solis Inverter Alarm Codes (Complete List), NO-Grid Fault - The inverter does not recognize the AC grid, Firmware Updating Guides & Firmware Files, Solis Inverter Current Firmware Versions [Master List], RHI-1P(5-10)K-HVES-5G inverters DSP firmware updating process, RHI-1P(5-10)K-HVES-5G inverters HMI firmware updating procedure, Solis-1P(3.6-10)K-4G inverters DSP firmware updating process, Solis-1P(3.6-10)K-4G inverters HMI firmware updating process, Solis-(25-40)K-4G inverter DSP firmware updating procedure, Solis-(25-40)K-4G inverter HMI firmware updating procedure, Solis-(50-66)K-4G inverters DSP firmware updating procedure, Solis-(50-66)K-4G inverters HMI firmware updating procedure, Solis-(75-100)K-5G-US inverter DSP Firmware Updating Procedure, Solis-(75-100)K-5G inverter HMI Firmware Updating Procedure, Solis-125K-EHV-5G inverter DSP firmware updating procedure, Solis-125K-EHV-5G inverter HMI firmware updating procedure, Solis-(185-255)K-EHV-5G inverter DSP firmware updating procedure, Solis-(185-255)K-EHV-5G inverter HMI firmware updating procedure, Setting a custom (user-defined) grid standard, US Grid Standards (values) // confidential //. Note: the SolisWiFilogger can only connect to 2.4 GHz networks and is unable to connect to 5 GHz networks. Otherwise, the communication quality may be affected. A Solis 5K inverter is used here as an example. Thanks for your help, my data logger looks like it is faulty. You will have full control of your system whenever and wherever you are. Scan the bar code on the logger [note: a cellular logger is shown in the photo but it has the same scanning process as the, You should see a message that says "Bound Successfully" and now you will need to set up the logger on the local, settings and then connecting to the network that starts with "AP" - this is the. Solis Data Loggers. 4: Once the computer IP is set with the above details open a web browser and navigate to 10.10.100.254 to login to LAN stickadmin page. Open the Local Connection Status, click. Open a web browser and enter "10.10.100.254" into the address bar 4. Solis inverter - Ginlong data logger - Neighbourhood | AGL Solis Pro - Apps on Google Play logger's local network which allows you to link it to the home network. logger can only connect to 2.4 GHz networks and is unable to connect to 5 GHz networks. Solis WiFi Data Logger Installation Guide, Start by pulling up the site on SolisCloud - tap "Plant" in the bottom left corner and then find the desired site in the displayed list of plants, Tap on the plant, then tap "Device" towards the top just to the right of "Overview", Tap "Datalogger" and then left-swipe the logger with your finger - you will see "Delete" in red to the right of the device, Tap "Delete" and then tap "Delete" again when asked if you want to disassociate the datalogger, "Deleted successfully" should appear - swipe down on the page to refresh it - the deleted datalogger should disappear from the device list as shown below, The deleted datalogger can now be installed on a different site/inverter, if that was the intention, A new datalogger can be installed at this site/on this inverter now that the old one has been removed. After the configuration is completed, click and back to the main page. If its not pingable, the password is good, the signal strength is good then login to the router and check the customers firewall protections. Thanks, The Boards Team. SolisCloud PV Monitoring Platform User Guide - Manuals+ Have contacted the company who sold me it. WiFi datalogger firmware is out of date If you run through the setup wizard and are still having problems I suggest you contact them. However, there is no guarantee that interference will not occur in a particular installation. Wi-Fi communication range: 300m in outdoor open area without obstruction. Firmware Version: 3.16.9. i have recently installed a solar inverter which has a data logger > having an issue connecting it to my wifi network but it works fine with . Solis Data Logging Stick - Solis Australasia If its not broadcasting conduct this procedure - https://www.youtube.com/watch?v=nUjcDcY8-Ws - If that doesn't fix the issue of it broadcasting please contact your local Solis Service Center and RMA the WIFI Stick. If you would like to change your settings or withdraw consent at any time, the link to do so is in our privacy policy accessible from our home page.. No-Grid - El inversor no reconoce la red. When there is a problem with any of the Solis inverters, plant operation and maintenance (O&M) professionals will appreciate that the GinlongPro APP will connect to the inverter's data logger. 1. Let us know how can we improve this article! Stepl: Enter the main page of the Soliscloud APP, and click the Add plant at the bottom. my Solis app has stopped giving info since about 1 am with message "Current plant offline, Please check network connection of plant device", is it just the wifi (or has the whole system gone down) and will re-booting the system put it right. You will need to have the, Unscrew the protective cap over the green COM port on the bottom of the inverter's wire box. Solis DLS-W WIFI Stick Troubleshooting : Service Centre SolisCloud intelligent software enables systems to be commissioned, monitored and maintained remotely saving time and money for installers and empowering . This should serve as a reminder to manually save your drafts if you wish to keep them. Help us improve this article with your feedback. The next screen should say "Configuration Complete" and you may tap "OK (3/3)" to finish up the commissioning, The system needs betweenten and fifteen minutesto sendit'sfirst report in, so please wait until the system begins to show data onSolisCloudbefore leaving the site, Did you find it helpful? AGL replaced it free of charge. We pay our respects to their Elders past, present and emerging. Can AGL please provide some support (a guide that is user friendly in english rather than fractured english) to help me connect and gain access to my PV data. SolisCloud is the new generation of intelligent PV system monitoring. Help us improve this article with your feedback. If you hate cookies, or are just on a diet, you can disable them altogether too. Solis is one of the oldest and largest global string inverter specialists that manufactures single-phase inverters, three phase inverters and energy stroage inverters for residential, commercial and utility scale PV systerms . What do I do next? Establecer el estndar de red personalizado Definido por usuario, Valores de la configuracin USER DEF para red 240v y 480v, Procedimiento de actualizacin remota de firmware, Reduccin de la potencia de salida del inversor Solis monofsico, Instalacin de cable RS-485 con conector circular, Configuracin de la direccin en inversor trifsico, Restablecer WiFi-Stick a la configuracin de fbrica, Registro de usuario final al sistema de monitoreo. Shows the connection status between the datalogger and the inverter. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. Monitoring Accessory Configured But Still Won't Link? solis GPRS Stick Datalogger Instruction Manual - Manuals+ Just note that the Freshdesk service is pretty big on some cookies (we love the choco-chip ones), and some portions of Freshdesk may not work properly if you disable cookies. If the WIFI stick shows the inverter but you don't have data on the monitoring portal follow these steps: If it is not pingable verify the router password again. No, Modified on: Tue, Oct 4, 2022 at 2:54 PM. Connect the antennae to the data logger; Plug the logger into the inverter - be sure the inverter is on with at least DC power; Open the Wi-Fi settings on your phone and then search for new networks . If the WIFI stick doesn't show a connected inverter check the address of the inverter. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. I too have recently tried to connect to the Ginlong data logger without success. It's probably just the datalogger that's lost connection. WiFi datalogger firmware is out of date. Wi-Fi trensmitting power: 802.11b/g/n: +20dBm/+18dBm/15dBm (Max) Data collection intervals: 5 minutes (adjustable:1-20 minutes) Preferences setting: Web server/Serial AT instruction. Go to the web browser and go to 10.10.100.254 and password is admin:admin. Replacing a Solis Data Logger : Solis Router signal strength is low 4. 4: Once the computer IP is set with the above details open a web browser and navigate to 10.10.100.254 to login to LAN stick, Solis DLS-G GPRS Datalogger setup and troubleshooting, Adding a new inverter to an existing EPM set-up, EPM 5G Plus- Abnormal Offline on Soliscloud. Select Network, fill in the IP address assigned by the router/network administrator, 1: Connect LAN stick to operational inverter to provide power to LAN stick. Enter the password for the network and then tap "Next". RHI-1P(5-10)K-HVES-5G Operation & Troubleshooting, Arc-Fault Alarm Troubleshooting for RHI-1P(5-10)K-HVES-5G, Advanced Hybrid DSP Issues - Replacing the DSP Board, Export Power Set and FailSafe Configuration, MET_Comm-FAIL and RS485 Fail Troubleshooting, Modbus Communications for RHI-1P(5-10)K-HVES-5G-US, Solis String-Level RSD Troubleshooting Procedures, Solis-(75-100)K-5G Tigo MLRSD Transmitter Disabling, Solis-1P(5-10)K-4G SunSpec MLRSD Transmitter Disabling, RHI-1P(5-10)K-5G SunSpec MLRSD Transmitter Disabling, RHI-1P(5-10)K-5G Tigo MLRSD Transmitter Disabling, Solis S1-W4G-ST WiFi & Cellular Data Logger Set Up Guide, Solis S3-WIFI-ST Wi-Fi Data Logger Setup Guide, Solis DLS-W WiFi Data Logger Installation Guide, Solis Cellular Data Logger Installation Guide, Solis DLS-C Cellular Data Logger - Carrier Compatibility, WiFi Stick Not Working With WiFi Extender Network. Gua rpida de instalacin del sistema de monitoreo para Mxico y Centro Amrica. With permission, you can test the firewall by removing the firewall for 5 minutes to see if the communication with the remote server changes to pingable. If you have not already been registered onSolisCloud, please see Step 18:SolisCloudMonitoring Platform. According to the website my data logger is offline. The scripts will process data from the WiFi and LAN Data . If it is set to one verify the WIFI stick has a good connection to the inverter. S-Energy 320W modules, Terminal Torque Specs by Inverter Model Series, Advisory Bulletin July 2019 - New DC Switch Color of Red on Single Phase, Application Notes: Rapid Shutdown AC Wiring with Multiple Inverters, Rule 21 Phase 1 July 26th Changes 1P and 3P, Solis RSD Letter For Jurisdiction Acceptance, Spring Terminals Installation and Removal, RHI-1P(5-10)K-5G with BYD HV Commissioning Guide, Solis RHI-1P(5-10)K-HVES-5G Installation Guide, 5 of 20 - Installing the External Meter and CTs, 7 of 20 - Inverter Menu Overview and Selecting the Grid Standard, 8 of 20 - Installing & Commissioning the BYD B-Box HV Battery, 9 of 20 - Installing LG Chem RESU10H Battery (Mounting), 10 of 20 - Installing LG Chem - Wiring and Commissioning, 11 of 20 - Energy Storage Operating Modes - Self Use, 12 of 20 - Energy Storage Operating Modes - Feed-In-Priority, 13 of 20 - Installing the Solis Autotransformer, 14 of 20 - Installing the Backup Loads Subpanel and Selecting Critical BreakersLoad, 15 of 20 - Energy Storage Operating Modes - Backup and Off-Grid Modes, 17 of 20 - Module-Level Rapid Shutdown (MLRSD), 18 of 20 - SolisCloud Monitoring Platform, Installation Overview & Single-Line Diagrams, Solis Inverter Alarm Codes (Complete List), NO-Grid Fault - The inverter does not recognize the AC grid, Firmware Updating Guides & Firmware Files, Solis Inverter Current Firmware Versions [Master List], RHI-1P(5-10)K-HVES-5G inverters DSP firmware updating process, RHI-1P(5-10)K-HVES-5G inverters HMI firmware updating procedure, Solis-1P(3.6-10)K-4G inverters DSP firmware updating process, Solis-1P(3.6-10)K-4G inverters HMI firmware updating process, Solis-(25-40)K-4G inverter DSP firmware updating procedure, Solis-(25-40)K-4G inverter HMI firmware updating procedure, Solis-(50-66)K-4G inverters DSP firmware updating procedure, Solis-(50-66)K-4G inverters HMI firmware updating procedure, Solis-(75-100)K-5G-US inverter DSP Firmware Updating Procedure, Solis-(75-100)K-5G inverter HMI Firmware Updating Procedure, Solis-125K-EHV-5G inverter DSP firmware updating procedure, Solis-125K-EHV-5G inverter HMI firmware updating procedure, Solis-(185-255)K-EHV-5G inverter DSP firmware updating procedure, Solis-(185-255)K-EHV-5G inverter HMI firmware updating procedure, Setting a custom (user-defined) grid standard, US Grid Standards (values) // confidential //. Ginlong Solis solar inverters Preamble. Connect to WIFI stick and verify firmware. Solis DLS-W WiFi Data Logger Installation Guide : Solis SolisCloud intelligent software enables systems to be commissioned, monitored and maintained remotely saving time and money for installers and empowering system owners with all the data they need. Press the button for 5 seconds to reset, 2 red lights are on and off at the same time, https://www.youtube.com/watch?v=nUjcDcY8-Ws, Solis DLS-G GPRS Datalogger setup and troubleshooting, Solis RHI HMI Update German Documentation. Solis Inverter Data Logger Issue. If you are verifying the connection on m.ginlong.com or pv.ginlong.com please allow 5-10 minutes for the updates to appear. Did you find it helpful? Router password is incorrect 3. Sorry we couldn't be helpful. Reset instruction for Solis Datalogger - YouTube Verify the RSSI (signal strength) is higher than 15%. Solis monitoring system is centered around photovoltaic power station, focusing on service operation and maintenance, Remotely controlled,adopting plug and play connection.Solis monitoring system can be monitored remotely by WIFI to provide users accurate and comprehensive data analysis and fault alarm at any time and place,, make product operation . If the connection is weak (1-2 bars) then it is recommended to install a. range extender to boost the signal strength where the logger is going to be. Let us know how can we improve this article! The [RESET] button on the back is used for the connection. Step1: Open the datalogger shell and install the SIM caret. I've recently installed a 6.6kW system for my home with a Solis Inverter. Solis datalogger installation instructions APP Enso Circle Space 2.1K subscribers Subscribe 84K views 3 years ago This instructional video shows you how to setup the WIFI monitoring on your. (DLB-W(Wifi),Lan Data Logger, Wifi Data Logger,S3-WIFI-ST,Celluar Data Logger,1500V PLC CCO, Solis-ATR-6K), For the duration of this period Ginlong guarantees the proper functions of the Products. This is to (1) ensure you have the correct, password and (2) ensure there is a strong enough. Yes You can learn more about what kind of cookies we use, why, and how from our Privacy policy. I need a better guide to enable me to connect via an Apple Mac and PC. cultures. AC Voltage Offset Procedure and Firmware Requirements, Service - Modbus Issues - Troubleshooting, LCD Protective Sticker Replacement Procedure. 4G Next COnfigurate Connection 15:30 Back Enter the plant name Done Plant Name If you hate cookies, or are just on a diet, you can disable them altogether too. We and our partners use cookies to Store and/or access information on a device. Select Network, fill in the IP address assigned by the router/network administrator. When configured correctly (see below), Solis invertors will send data about their performance every 5 minutes to code waiting to receive the data. We and our partners use data for Personalised ads and content, ad and content measurement, audience insights and product development. View real-time data of the PV plant , and get equipment condition is controlled at anytime and anywhere. Step1: Select Owner or Installer for email address registration. The device must be installed away from the strong magnetic field produced by large electrical appliances such as microwave ovens, refrigerators, telephone, metal walls, etc. Manage Settings I have set up an account on Ginlongmonitoring.com and entered the details of the data logger. https://www.youtube.com/watch?v=0F0aGeTOYw8. Solis datalogger installation instructions APP - YouTube WiFi Data Logger - Solis Monitoring equipmentus - Ginlong Step 1: Use your phone to scan the QR code to download and register the Solis Cloud APP. Any changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. SolisCloud Step 2: If it is a new data logger, please configure it first, then click the " Willi configure". This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. No-Grid - El inversor no reconoce la red. To view the purposes they believe they have legitimate interest for, or to object to this data processing use the vendor list link below. 1. If you have not already been registered on SolisCloud, please see Step 18: SolisCloud . It may also be affected by lighting storms. Just note that the Freshdesk service is pretty big on some cookies (we love the choco-chip ones), and some portions of Freshdesk may not work properly if you disable cookies. Solarman Data Loggers (4-pin only) DLS-W: WiFi only data logger; DLS-L: LAN only data logger; DLS-C: 4G cellular only data logger; Solis is no longer selling these products in the US; Our distributors likely still have stock of these products but we are not promoting them; Solarman loggers do not support remote settings changes or firmware updates Solis monitoring system is centered around photovoltaic power station, focusing on service operation and maintenance, Remotely controlled,adopting plug and play connection. Go to your web browser - Input 10.10.100.254, 4. Solis S1-W4G-ST WiFi & Cellular Data Logger Set Up Guide; Solis S3-WIFI-ST Wi-Fi Data Logger Setup Guide; Solis DLS-W WiFi Data Logger Installation Guide; Solis Cellular Data Logger Installation Guide; Solis DLS-C Cellular Data Logger - Carrier Compatibility; Replacing a Solis Data Logger; WiFi password changed first report in, so please wait until the system begins to show data on. Reset WiFi Stick to Factory Settings : Solis ContactPlease contact us if you have any technical problems in terms of the product. Connect the WIFI stick by attaching it to the green plug on the bottom of all Solis inverters. :). 2. Step 1: Use your phone to scan the QR code to download and register the Solis Cloud APP. 3: Set a manual IP for the computer using the following information -, (The IP of the computer must be with 10.10.100.XXX range to configure the LAN stick). Press the button for 5 seconds to reset2 red lights are on and off at the same time. If failed, re-do the configuration process or contact the after-sale engineers. Solis Data Loggers. Solis inverter - Ginlong data logger Solar, Batteries & Technology Questions and discussion about solar, batteries, and other renewable energy technology Solis inverter - Ginlong data logger Comet 08-05-2018 09:43 PM 6 Replies 1 Like 45040 Views Hi We have just had a solar system installed. This article is a guide for how to replace a Solis Data Logger on an existing system: one that has already been created in SolisCloud. You should see a message that says "Bound Successfully" and now you will need to set up the logger on the localWiFinetwork. This is to (1) ensure you have the correctWiFipassword and (2) ensure there is a strong enoughWiFisignal at the inverter for there to be a stable connection. i cannot connect my solar wifi data logger to my wifi but it gets Unscrew the protective cap over the green COM port on the bottom of the inverter's wire box. In order to to set an IP address you can use a Mobile Phone, Tablet or Computer. Solar Inverters | String Inverters | Energy storage inverters - Ginlong
Best Homemade Face Mask For Rosacea, Articles S
Best Homemade Face Mask For Rosacea, Articles S